IPASSIGN - Software 2701094
IPAssign is an easy to use tool for setting the IP address of devices which rely on BOOTP. No installation or administrative rights are required to use IPAssign. This product is free and only available from the "Downloads" tab.
Product details
IPAssign is an easy to use tool for setting the IP address of devices which rely on BOOTP. No installation or administrative rights are required to use IPAssign. With a simple selection, you can filter out all of the devices except those from Phoenix Contact.
- Phoenix Contact Manuals
- FL SWITCH 2000 Series
- Installation and startup manual
Phoenix Contact FL SWITCH 2000 Series Installation And Startup Manual
- page of 228 Go / 228
Table of Contents
- Product Changes
- For Your Safety
- Qualification of Users
- Identification of Warning Notes
- Unauthorized Network Access
- Properties of the Devices
- Properties and Versions
- FL SWITCH 2Xxx Device Versions
- FL NAT 2Xxx Device Versions
- Description of Ethernet Interfaces
- Device Functions
- Overview Table of the Functions
- Status and Diagnostic Indicators
- Description of the Integrated Fiberglass Transceivers
- Description of the Combo Ports
- Integrated Fiberglass Transceivers with an SC Pin Connector
- Using the SFP Slots (Principle)
- Elements of the SFP Modules
- Mounting the SFP Modules
- Inserting the SFP Modules (Example)
- Using the (Micro)Sd Card
- Position of the SD Card Slot (Left) and Position of the MI
- Assignment of the Ethernet Connectors
- Pin Assignment of RJ45 Connectors
- Mounting and Installation
- Functional Grounding
- General Information
- Pin Assignment of D-Coded M12 Connectors
- Pin Assignment of X-Coded M12 Connectors
- Dimensions of 16-Port Versions in a Narrow Housing
- Device Dimensions
- FL SWITCH 20Xx/21Xx/22Xx/23Xx and FL NAT 2Xxx
- Elements of the Devices
- Elements of the FL SWITCH 20Xx/21Xx/22Xx/23Xx and
- Key for FL SWITCH 20Xx/21Xx/22Xx/23Xx and FL NAT 2Xxx
- Mounting and Removing the Devices
- Snapping the Device Onto the DIN Rail
- Removing the Device
- Installing the Devices
- Selection of Conductors/Ferrules/Screwdrivers
- Selecting the Conductors
- Specifications for Ferrules
- Operating the Device with One Power Supply (Example)
- Redundant Operation with Two Power Supplies (Example)
- Connecting a Relay to the Digital Alarm Output
- FL SWITCH 20Xxf
- Dimensions of the 8-Port Version in a Flat Housing
- Elements of the FL SWITCH 20Xxf Devices
- Key for FL SWITCH 20Xxf
- Selection of Conductors/Ferrules
- FL SWITCH 24Xx/25Xx
- Dimensions of 16-Port Versions
- Elements of the FL SWITCH 24Xx/25Xx Devices
- Key for FL SWITCH 24Xx/25Xx
- Supplying the Switch Using One Voltage Source
- Supplying the Switch Using Two Voltage Sources
- FL SWITCH 26Xx/27Xx
- Dimensions of the FL SWITCH 26Xx/27Xx Devices
- Elements of the FL SWITCH 26Xx/27Xx Devices
- Key for FL SWITCH 26Xx/27Xx
- Figure 324 Drill Holes
- Pin Assignment for the Power Supply Via M12 Connectors with
- Startup and Function
- Delivery State/Factory Default
- Initial IP Configuration in the Delivery State
- Configuration in the Delivery State
- Using Smart Mode
- Entering Smart Mode
- Selecting the Desired Setting
- Operation in Universal Mode
- Exiting Smart Mode
- Possible Operating Modes in Smart Mode
- Operation in PROFINET Mode
- Operation in Ethernet/Ip Mode
- Operation with Default IP Address
- Resetting the IP Configuration
- Operation in Unmanaged Mode
- Assigning IP Parameters Via Bootp
- Assigning the IP Address Using FL NETWORK MANAGER BASIC
- Figure 41 Settings for the Bootp Server
- Figure 42 Bootp Server
- Figure 43: FL NETWORK MANAGER with Bootp/Dhcp Reservation List
- Assigning the IP Address Using Ipassign.exe
- Figure 44 "IP Address Request Listener" Window
- Figure 45 "Set IP Address" Window with Incorrect Settings
- Figure 46 "Assign IP Address" Window
- Technical Data
- Fl Switch 2005
- Fl Switch 2008
- Fl Switch 2008F
- Fl Switch 2016
- Fl Switch 2105
- Fl Switch 2108
- Fl Switch 2116
- Fl Switch 2205
- Fl Switch 2208
- Fl Switch 2208C
- Fl Switch 2208 Pn
- Fl Switch 2207-Fx
- Fl Switch 2207-Fx Sm
- Fl Switch 2206-2Fx
- Fl Switch 2206C-2Fx
- Fl Switch 2206-2Fx Sm
- Fl Switch 2206-2Fx St
- Fl Switch 2206-2Fx Sm St
- Fl Switch 2206-2Sfx
- Fl Switch 2206-2Sfx Pn
- Fl Switch 2204-2Tc-2Sfx
- Fl Switch 2216
- Fl Switch 2216 Pn
- Fl Switch 2214-2Fx
- Fl Switch 2214-2Fx Sm
- Fl Switch 2214-2Sfx
- Fl Switch 2214-2Sfx Pn
- Fl Switch 2212-2Tc-2Sfx
- Fl Switch 2308
- Fl Switch 2308 Pn
- Fl Switch 2306-2Sfp
- Fl Switch 2306-2Sfp Pn
- Fl Switch 2304-2Gc-2Sfp
- Fl Switch 2316
- Fl Switch 2316 Pn
- Fl Switch 2314-2Sfp
- Fl Switch 2314-2Sfp Pn
- Fl Switch 2312-2Gc-2Sfp
- Fl Switch 2408
- Fl Switch 2408 Pn
- Fl Switch 2406-2Sfx
- Fl Switch 2406-2Sfx Pn
- Fl Switch 2404-2Tc-2Sfx
- Fl Switch 2416
- Fl Switch 2416 Pn
- Fl Switch 2414-2Sfx
- Fl Switch 2414-2Sfx Pn
- Fl Switch 2412-2Tc-2Sfx
- Fl Switch 2508
- Fl Switch 2508/K1
- Fl Switch 2508 Pn
- Fl Switch 2506-2Sfp
- Fl Switch 2506-2Sfp/K1
- Fl Switch 2506-2Sfp Pn
- Fl Switch 2504-2Gc-2Sfp
- Fl Switch 2516
- Fl Switch 2516 Pn
- Fl Switch 2514-2Sfp
- Fl Switch 2514-2Sfp Pn
- Fl Switch 2512-2Gc-2Sfp
- Fl Switch 2608
- Fl Switch 2608 Pn
- Fl Switch 2708
- Fl Switch 2708 Pn
- Fl Nat 2008
- Fl Nat 2208
- Fl Nat 2304-2Gc-2Sfp
A Appendix For Document Lists
- A 1 List of Figures
- A 2 List of Tables
Advertisement
Quick Links
- 1 Status and Diagnostic Indicators
- Download this manual
- Table of Contents 3
- A Appendix For Document Lists 221
Related Manuals for Phoenix Contact FL SWITCH 2000 Series
Summary of Contents for Phoenix Contact FL SWITCH 2000 Series
- Page 1 Installation and startup of the FL SWITCH 2000 and FL NAT 2000 product families User manual...
- Page 2 FL SWITCH 2212-2TC-2SFX 2702907 FL SWITCH 2514-2SFP 1043499 FL SWITCH 2308 2702652 FL SWITCH 2514-2SFP PN 1089154 FL SWITCH 2308 PN 1009220 FL SWITCH 2512-2GC-2SFP 1088856 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com...
Page 3: Table Of Contents
- Page 4 FL SWITCH 2208C....................73 5.11 FL SWITCH 2208 PN ..................75 5.12 FL SWITCH 2207-FX ..................78 5.13 FL SWITCH 2207-FX SM ..................81 5.14 FL SWITCH 2206-2FX ..................83 5.15 FL SWITCH 2206C-2FX ..................86 4 / 226 PHOENIX CONTACT 108997_en_04...
- Page 5 FL SWITCH 2414-2SFX PN ................170 5.48 FL SWITCH 2412-2TC-2SFX ................172 5.49 FL SWITCH 2508 ....................175 5.50 FL SWITCH 2508/K1..................177 5.51 FL SWITCH 2508 PN ..................179 5.52 FL SWITCH 2506-2SFP ..................182 5 / 226 PHOENIX CONTACT 108997_en_04...
- Page 6 FL SWITCH 2708 PN ..................210 5.65 FL NAT 2008 ..................... 212 5.66 FL NAT 2208 ..................... 214 5.67 FL NAT 2304-2GC-2SFP................... 216 Appendix for document lists....................221 List of figures ..................... 221 List of tables ...................... 223 6 / 226 PHOENIX CONTACT 108997_en_04...
Page 7: For Your Safety
Page 8: unauthorized network access, page 9: properties of the devices.
- Page 10 PROFINET mode 6 x RJ45 2 x SFP FL SWITCH 2504-2GC-2SFP 4 x RJ45 2 x combo, 2 x SFP FL SWITCH 2516 16 x RJ45 FL SWITCH 2516 PN PROFINET mode 16 x RJ45 10 / 226 PHOENIX CONTACT 108997_en_04...
Page 11: Fl Nat 2Xxx Device Versions
Page 12: overview table of the functions.
- Page 13 Security MAC-based port security RADIUS authentication (IEEE 802.1X) Layer 3 functions (FL NAT versions only) Static routing 1:1 NAT Port forwarding (1:n NAT) Virtual NAT No FL NAT versions are available for these series. 13 / 226 PHOENIX CONTACT 108997_en_04...
Page 14: Status And Diagnostic Indicators
Page 15: description of the integrated fiberglass transceivers, page 16: using the sfp slots (principle), page 17: using the (micro)sd card.
- Page 18 During reading on a 5/8-port device, the entries for configuration of ports 9 to 16 are ignored. Inversely, the parameters of ports 9 to 16 are set to the factory default when the config- uration of a 5/8-port device is read on a 16-port device. 18 / 226 PHOENIX CONTACT 108997_en_04...
Page 19: Mounting And Installation
Page 20: pin assignment of d-coded m12 connectors, page 21: fl switch 20xx/21xx/22xx/23xx and fl nat 2xxx, page 22: elements of the devices, page 23: snapping the device onto the din rail, page 24: installing the devices, page 25: operating the device with one power supply (example), page 26: connecting a relay to the digital alarm output, page 27: fl switch 20xxf, page 28: mounting and removing the devices, page 29: installing the devices, page 30: fl switch 24xx/25xx, page 31: elements of the devices, page 32: removing the device, page 33: installing the devices, page 34: supplying the switch using one voltage source.
- Page 35 This error message can be prevented by connecting the supply voltage to both US1/US2 terminal blocks in parallel (as shown in Figure 319) or by deactivating redundant power supply monitoring in web-based management or via SNMP. 35 / 226 PHOENIX CONTACT 108997_en_04...
Page 36: Fl Switch 26Xx/27Xx
Page 37: mounting and removing the devices, page 38: installing the devices.
- Page 39 Ensure fuse protection for the power supply that is suitable for your design. If the permissible current carrying capacity is exceeded, this may result in damage to the connectors, the electronic components, and to the PCB of the device. We recommend using pre-assembled cables. 39 / 226 PHOENIX CONTACT 108997_en_04...
- Page 40 FL SWITCH 2000 / FL NAT 2000 40 / 226 PHOENIX CONTACT 108997_en_04...
Page 41: Startup And Function
Page 42: configuration in the delivery state, page 43: using smart mode, page 44: possible operating modes in smart mode, page 45: operation in profinet mode, page 46: operation in unmanaged mode, page 47: assigning the ip address using fl network manager basic, page 48: figure 42 bootp server, page 49: assigning the ip address using ipassign.exe, page 50: figure 45 "set ip address" window with incorrect settings.
- Page 51 • Click on the “Zurück” (Back) button. To exit the IP address assignment: • Click on the “Fertig stellen” (Finish) button. The IP parameters set here can be changed in web-based management, if required. 51 / 226 PHOENIX CONTACT 108997_en_04...
- Page 52 FL SWITCH 2000 / FL NAT 2000 52 / 226 PHOENIX CONTACT 108997_en_04...
Page 53: Technical Data
- Page 54 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 54 / 226 PHOENIX CONTACT 108997_en_04...
Page 55: Fl Switch 2008
- Page 56 Maximum power dissipation for nominal condition 4.86 W (At U = 18 V DC and 60°C ambient temperature) Test section for one minute 500 V DC Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 56 / 226 PHOENIX CONTACT 108997_en_04...
Page 57: Fl Switch 2008F
- Page 58 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 58 / 226 PHOENIX CONTACT 108997_en_04...
Page 59: Fl Switch 2016
- Page 60 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 60 / 226 PHOENIX CONTACT 108997_en_04...
Page 61: Fl Switch 2105
- Page 62 (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.25 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² 62 / 226 PHOENIX CONTACT 108997_en_04...
- Page 63 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1 UL, Canada CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010- 1-12, Ed.3 Further approvals cULus Listed, EAC, CC-Link IE Field 63 / 226 PHOENIX CONTACT 108997_en_04...
Page 64: Fl Switch 2108
- Page 65 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 65 / 226 PHOENIX CONTACT 108997_en_04...
Page 66: Fl Switch 2116
- Page 67 Maximum power dissipation for nominal condition 12.6 W (At U = 18 V DC and 60°C ambient temperature) Test section for one minute 500 V DC Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 67 / 226 PHOENIX CONTACT 108997_en_04...
Page 68: Fl Switch 2205
- Page 69 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 69 / 226 PHOENIX CONTACT 108997_en_04...
- Page 70 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 70 / 226 PHOENIX CONTACT 108997_en_04...
Page 71: Fl Switch 2208
- Page 72 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 72 / 226 PHOENIX CONTACT 108997_en_04...
Page 73: Fl Switch 2208C
- Page 74 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 74 / 226 PHOENIX CONTACT 108997_en_04...
Page 75: Fl Switch 2208 Pn
- Page 76 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 76 / 226 PHOENIX CONTACT 108997_en_04...
- Page 77 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 77 / 226 PHOENIX CONTACT 108997_en_04...
Page 78: Fl Switch 2207-Fx
- Page 79 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 79 / 226 PHOENIX CONTACT 108997_en_04...
- Page 80 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates ATEX II 3 G Ex ec IIC T4 Gc IECEx Ex ec IIC T4 Gc UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5 80 / 226 PHOENIX CONTACT 108997_en_04...
Page 81: Fl Switch 2207-Fx Sm
- Page 82 100 Mbps (full duplex) Transmission length 36000 m (fiberglass with F-G 9/125 0.36 dB/km) Transmission length 32000 m (fiberglass with F-G 9/125 0.4 dB/km) Transmission length 26000 m (fiberglass with F-G 9/125 0.5 dB/km) Wavelength 1300 nm 82 / 226 PHOENIX CONTACT 108997_en_04...
Page 83: Fl Switch 2206-2Fx
- Page 84 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 9 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 84 / 226 PHOENIX CONTACT 108997_en_04...
- Page 85 1.5 A (U = Min, T = Max, DO = Max) Maximum power dissipation for nominal condition 6.75 W (U = Min, T = Max, DO = Max) Test section for one minute 500 V DC 85 / 226 PHOENIX CONTACT 108997_en_04...
Page 86: Fl Switch 2206C-2Fx
- Page 87 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 87 / 226 PHOENIX CONTACT 108997_en_04...
- Page 88 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) Conformity with EMC directives Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU 88 / 226 PHOENIX CONTACT 108997_en_04...
Page 89: Fl Switch 2206-2Fx Sm
- Page 90 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 9 V DC ... 57 V DC Typical current consumption 235 mA (at U = 24 V DC and 25 °C ambient temperature) 90 / 226 PHOENIX CONTACT 108997_en_04...
Page 91: Fl Switch 2206-2Fx St
- Page 92 Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.25 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² 92 / 226 PHOENIX CONTACT 108997_en_04...
- Page 93 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 93 / 226 PHOENIX CONTACT 108997_en_04...
Page 94: Fl Switch 2206-2Fx Sm St
- Page 95 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 95 / 226 PHOENIX CONTACT 108997_en_04...
- Page 96 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 96 / 226 PHOENIX CONTACT 108997_en_04...
Page 97: Fl Switch 2206-2Sfx
- Page 98 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100 Mbps (full duplex) Transmission length up to 40 km (Depending on the fiber/SFP module used) 98 / 226 PHOENIX CONTACT 108997_en_04...
Page 99: Fl Switch 2206-2Sfx Pn
- Page 100 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 100 / 226 PHOENIX CONTACT 108997_en_04...
- Page 101 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 101 / 226 PHOENIX CONTACT 108997_en_04...
Page 102: Fl Switch 2204-2Tc-2Sfx
- Page 103 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 103 / 226 PHOENIX CONTACT 108997_en_04...
- Page 104 Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A 104 / 226 PHOENIX CONTACT 108997_en_04...
Page 105: Fl Switch 2216
- Page 106 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 106 / 226 PHOENIX CONTACT 108997_en_04...
Page 107: Fl Switch 2216 Pn
- Page 108 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 108 / 226 PHOENIX CONTACT 108997_en_04...
- Page 109 EN 61000-6-2 EN 61000-6-3 (conducted emissions) Class B Interference emission EN 61000-6-2 EN 61000-6-3 (noise emission) Class B Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 109 / 226 PHOENIX CONTACT 108997_en_04...
Page 110: Fl Switch 2214-2Fx
- Page 111 Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 111 / 226 PHOENIX CONTACT 108997_en_04...
- Page 112 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates ATEX II 3 G Ex ec IIC T4 Gc IECEx Ex ec IIC T4 Gc UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5 112 / 226 PHOENIX CONTACT 108997_en_04...
Page 113: Fl Switch 2214-2Fx Sm
- Page 114 100 Mbps (full duplex) Transmission length 36000 m (fiberglass with F-G 9/125 0.36 dB/km) Transmission length 32000 m (fiberglass with F-G 9/125 0.4 dB/km) Transmission length 26000 m (fiberglass with F-G 9/125 0.5 dB/km) Wavelength 1300 nm 114 / 226 PHOENIX CONTACT 108997_en_04...
Page 115: Fl Switch 2214-2Sfx
- Page 116 100 % (7 days a week, 24 hours a day)) Signal contact Output name Digital output Control voltage range 12 V DC ... 57 V DC Current carrying capacity typ. 100 mA max. 0.7 A (1 minute) 116 / 226 PHOENIX CONTACT 108997_en_04...
- Page 117 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 117 / 226 PHOENIX CONTACT 108997_en_04...
Page 118: Fl Switch 2214-2Sfx Pn
- Page 119 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing 119 / 226 PHOENIX CONTACT 108997_en_04...
- Page 120 EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates ATEX II 3 G Ex ec IIC T4 Gc IECEx Ex ec IIC T4 Gc UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5 120 / 226 PHOENIX CONTACT 108997_en_04...
Page 121: Fl Switch 2212-2Tc-2Sfx
- Page 122 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100 Mbps (full duplex) Transmission length up to 40 km (Depending on the fiber/SFP module used) 122 / 226 PHOENIX CONTACT 108997_en_04...
- Page 123 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA 123 / 226 PHOENIX CONTACT 108997_en_04...
Page 124: Fl Switch 2308
- Page 125 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 125 / 226 PHOENIX CONTACT 108997_en_04...
Page 126: Fl Switch 2308 Pn
- Page 127 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 127 / 226 PHOENIX CONTACT 108997_en_04...
- Page 128 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA, PROFINET 128 / 226 PHOENIX CONTACT 108997_en_04...
Page 129: Fl Switch 2306-2Sfp
- Page 130 1.5 A (U = Min, T = Max, DO = Max) Maximum power dissipation for nominal condition 9 W (U = Min, T = Max, DO = Max) Test section for one minute 500 V DC 130 / 226 PHOENIX CONTACT 108997_en_04...
Page 131: Fl Switch 2306-2Sfp Pn
- Page 132 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 132 / 226 PHOENIX CONTACT 108997_en_04...
- Page 133 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion B Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 133 / 226 PHOENIX CONTACT 108997_en_04...
Page 134: Fl Switch 2304-2Gc-2Sfp
- Page 135 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100/1000 Mbps (full duplex) Transmission length up to 80 km (depending on the SFP module used) 135 / 226 PHOENIX CONTACT 108997_en_04...
- Page 136 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 136 / 226 PHOENIX CONTACT 108997_en_04...
Page 137: Fl Switch 2316
- Page 138 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 138 / 226 PHOENIX CONTACT 108997_en_04...
Page 139: Fl Switch 2316 Pn
- Page 140 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 140 / 226 PHOENIX CONTACT 108997_en_04...
- Page 141 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA, PROFINET 141 / 226 PHOENIX CONTACT 108997_en_04...
Page 142: Fl Switch 2314-2Sfp
- Page 143 2 A (U = Min, T = Max, DO = Max) Maximum power dissipation for nominal condition 15.6 W (U = Min, T = Max, DO = Max) Test section for one minute 500 V DC 143 / 226 PHOENIX CONTACT 108997_en_04...
Page 144: Fl Switch 2314-2Sfp Pn
- Page 145 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.25 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 9 mm 145 / 226 PHOENIX CONTACT 108997_en_04...
- Page 146 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 146 / 226 PHOENIX CONTACT 108997_en_04...
Page 147: Fl Switch 2312-2Gc-2Sfp
- Page 148 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100/1000 Mbps (full duplex) Transmission length up to 80 km (Depending on the fiber/SFP module used) 148 / 226 PHOENIX CONTACT 108997_en_04...
- Page 149 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, DNV GL, LR, NK, RINA 149 / 226 PHOENIX CONTACT 108997_en_04...
Page 150: Fl Switch 2408
- Page 151 Shock (operation) 30g (EN 60068-2-27) Conformity with EMC directives Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A 151 / 226 PHOENIX CONTACT 108997_en_04...
Page 152: Fl Switch 2408 Pn
- Page 153 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 160 mA (at U = 24 V DC and 25 °C ambient temperature) 153 / 226 PHOENIX CONTACT 108997_en_04...
Page 154: Fl Switch 2406-2Sfx
- Page 155 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 155 / 226 PHOENIX CONTACT 108997_en_04...
- Page 156 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 156 / 226 PHOENIX CONTACT 108997_en_04...
Page 157: Fl Switch 2406-2Sfx Pn
- Page 158 Interface: SFP module Number of interfaces Connection method SFP ports Transmission physics Depending on the SFP module Transmission speed 100 Mbps (full duplex) Transmission length up to 40 km (depending on the SFP module used) 158 / 226 PHOENIX CONTACT 108997_en_04...
Page 159: Fl Switch 2404-2Tc-2Sfx
- Page 160 Push-in spring connection Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² 160 / 226 PHOENIX CONTACT 108997_en_04...
- Page 161 = 24 V DC and 25 °C ambient temperature) Max. current consumption 290 mA (U = min, T = max) Maximum power dissipation for nominal condition 5.44 W (U = max, T = max) Test section for one minute 500 V DC 161 / 226 PHOENIX CONTACT 108997_en_04...
Page 162: Fl Switch 2416
- Page 163 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing 163 / 226 PHOENIX CONTACT 108997_en_04...
- Page 164 EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 Further approvals 164 / 226 PHOENIX CONTACT 108997_en_04...
Page 165: Fl Switch 2416 Pn
- Page 166 Shock (operation) 30g (EN 60068-2-27) Conformity with EMC directives Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A 166 / 226 PHOENIX CONTACT 108997_en_04...
Page 167: Fl Switch 2414-2Sfx
- Page 168 Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) Interface: SFP module Number of interfaces Connection method SFP ports 168 / 226 PHOENIX CONTACT 108997_en_04...
- Page 169 EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Approvals / Certificates UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 169 / 226 PHOENIX CONTACT 108997_en_04...
Page 170: Fl Switch 2414-2Sfx Pn
- Page 171 = 24 V DC and 25 °C ambient temperature) Max. current consumption 440 mA (U = min, T = max) Maximum power dissipation for nominal condition 8.26 W (U = max, T = max) Test section for one minute 500 V DC 171 / 226 PHOENIX CONTACT 108997_en_04...
Page 172: Fl Switch 2412-2Tc-2Sfx
- Page 173 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing 173 / 226 PHOENIX CONTACT 108997_en_04...
- Page 174 Conformance with EMC Directive 2014/30/EU Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A 174 / 226 PHOENIX CONTACT 108997_en_04...
Page 175: Fl Switch 2508
- Page 176 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 230 mA (at U = 24 V DC and 25 °C ambient temperature) 176 / 226 PHOENIX CONTACT 108997_en_04...
Page 177: Fl Switch 2508/K1
- Page 178 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 178 / 226 PHOENIX CONTACT 108997_en_04...
Page 179: Fl Switch 2508 Pn
- Page 180 Push-in spring connection Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² 180 / 226 PHOENIX CONTACT 108997_en_04...
- Page 181 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 181 / 226 PHOENIX CONTACT 108997_en_04...
Page 182: Fl Switch 2506-2Sfp
- Page 183 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 260 mA (at U = 24 V DC and 25 °C ambient temperature) 183 / 226 PHOENIX CONTACT 108997_en_04...
Page 184: Fl Switch 2506-2Sfp/K1
- Page 185 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 185 / 226 PHOENIX CONTACT 108997_en_04...
- Page 186 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 186 / 226 PHOENIX CONTACT 108997_en_04...
Page 187: Fl Switch 2506-2Sfp Pn
- Page 188 = 24 V DC and 25 °C ambient temperature) Max. current consumption 350 mA (U = min, T = max) Maximum power dissipation for nominal condition 6.46 W (U = max, T = max) Test section for one minute 500 V DC 188 / 226 PHOENIX CONTACT 108997_en_04...
Page 189: Fl Switch 2504-2Gc-2Sfp
- Page 190 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 190 / 226 PHOENIX CONTACT 108997_en_04...
- Page 191 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 191 / 226 PHOENIX CONTACT 108997_en_04...
Page 192: Fl Switch 2516
- Page 193 Stripping length 10 mm Interface: Ethernet (RJ45) Number of interfaces Connection method RJ45 Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100/1000 Mbps Transmission length 100 m (per segment) 193 / 226 PHOENIX CONTACT 108997_en_04...
Page 194: Fl Switch 2516 Pn
- Page 195 Push-in spring connection Note on the connection method Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² 195 / 226 PHOENIX CONTACT 108997_en_04...
- Page 196 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 196 / 226 PHOENIX CONTACT 108997_en_04...
Page 197: Fl Switch 2514-2Sfp
- Page 198 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 460 mA (at U = 24 V DC and 25 °C ambient temperature) 198 / 226 PHOENIX CONTACT 108997_en_04...
Page 199: Fl Switch 2514-2Sfp Pn
- Page 200 Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. Conductor cross section AWG max. Stripping length 10 mm 200 / 226 PHOENIX CONTACT 108997_en_04...
- Page 201 EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A 201 / 226 PHOENIX CONTACT 108997_en_04...
Page 202: Fl Switch 2512-2Gc-2Sfp
- Page 203 Note on the connection method Auto negotiation and autocrossing Transmission physics Depending on the SFP module Transmission speed 10/100/1000 Mbps (full duplex) Transmission length up to 80 km (Depending on the fiber/SFP module used) 203 / 226 PHOENIX CONTACT 108997_en_04...
Page 204: Fl Switch 2608
- Page 205 M12 connector, (A-coded) Interface: Ethernet Number of interfaces Connection method M12 connectors, D-coded Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100 Mbps Transmission length 100 m (per segment) 205 / 226 PHOENIX CONTACT 108997_en_04...
Page 206: Fl Switch 2608 Pn
- Page 207 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 9 V DC ... 57 V DC Typical current consumption 180 mA (at U = 24 V DC and 25 °C ambient temperature) 207 / 226 PHOENIX CONTACT 108997_en_04...
Page 208: Fl Switch 2708
- Page 209 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 209 / 226 PHOENIX CONTACT 108997_en_04...
Page 210: Fl Switch 2708 Pn
- Page 211 EN 61000-6-3 (conducted emissions) Class B Interference emission EN 61000-6-3 (conducted emissions) Class B Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 211 / 226 PHOENIX CONTACT 108997_en_04...
Page 212: Fl Nat 2008
- Page 213 EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion 213 / 226 PHOENIX CONTACT 108997_en_04...
Page 214: Fl Nat 2208
- Page 215 Supply voltage 24 V DC (redundant) Residual ripple 3.6 V (within the permitted voltage range) Supply voltage range 9 V DC ... 57 V DC Typical current consumption 185 mA (at U = 24 V DC and 25 °C ambient temperature) 215 / 226 PHOENIX CONTACT 108997_en_04...
Page 216: Fl Nat 2304-2Gc-2Sfp
- Page 217 Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). pluggable Conductor cross section solid min. 0.08 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.08 mm² 217 / 226 PHOENIX CONTACT 108997_en_04...
- Page 218 Mechanical tests Mechanical tests Free fall in accordance with EN 61131-2 Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Shock (operation) 30g (EN 60068-2-27) 218 / 226 PHOENIX CONTACT 108997_en_04...
- Page 219 CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16 UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4 Class I, Zone 2, IIC T4 Further approvals cULus Listed, EAC, ABS, BSH, DNV GL, LR, NK, RINA 219 / 226 PHOENIX CONTACT 108997_en_04...
- Page 220 FL SWITCH 2000 / FL NAT 2000 220 / 226 PHOENIX CONTACT 108997_en_04...
Page 221: A Appendix For Document Lists
- Page 222 FL NETWORK MANAGER with BootP/DHCP reservation list shown ....................48 Figure 44: “IP Address Request Listener” window ..........49 Figure 45: “Set IP Address” window with incorrect settings ......... 50 Figure 46: “Assign IP Address” window ............... 50 222 / 226 PHOENIX CONTACT 108997_en_04...
Page 223: A 2 List Of Tables
- Page 224 FL SWITCH 2000 / FL NAT 2000 224 / 226 PHOENIX CONTACT 108997_en_04...
- Page 225 The receipt of technical documentation (in particular user documentation) does not constitute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observing the applicable standards and regulations.
- Page 226 Should you have any suggestions or recommendations for improvement of the contents and layout of our manuals, please send your comments to: [email protected] 226 / 226 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com...
- Page 228 PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8 32825 Blomberg, Germany Phone: +49 5235 3-00 Fax: +49 5235 3-41200 E-mail: [email protected] phoenixcontact.com...
This manual is also suitable for:
Rename the bookmark, delete bookmark, delete from my manuals, upload manual.
IMAGES
VIDEO